Capacities
Annealing furnaces
Four industrial furnaces up to 12.8 m long, 100 t load capacity and 750 °C, with 20 t and 64 t cranes.
Four furnaces
We choose the furnace to fit your weldment
Weldments can be long and narrow, or short but wide and tall. That is why we run four furnaces of different sizes and load capacities.
- W × H
- 3.4 × 3.6 m
- Depth
- 12.0 m
- Max. temperature
- 650 °C
- W × H
- 3.0 × 2.7 m
- Depth
- 4.4 m
- Max. temperature
- 580 °C
- W × H
- 5.3 × 4.0 m
- Depth
- 6.4 m
- Max. temperature
- 650 °C
- W × H
- 3.9 × 4.5 m
- Depth
- 12.8 m
- Max. temperature
- 750 °C
Furnace specifications
| Specification | Furnace 1 | Furnace 2 | Furnace 3 | Furnace 4 |
|---|---|---|---|---|
| Width | 3,400 mm | 3,000 mm | 5,300 mm | 3,900 mm |
| Height | 3,600 mm | 2,700 mm | 4,000 mm | 4,500 mm |
| Depth | 12,000 mm | 4,400 mm | 6,400 mm | 12,800 mm |
| Load capacity | 100,000 kg | 8,000 kg | 80,000 kg | 60,000 kg |
| Maximum temperature | 650 °C | 580 °C | 650 °C | 750 °C |
| Temperature tolerance | ±10 °C | ±20 °C | ±10 °C | ±10 °C |
| Heating | electric | electric | electric | electric |
| Thermocouples on part | – | – | up to 12 thermocouples | up to 12 thermocouples |

Lifting equipment
20 t and 64 t cranes
We handle loading into the furnace and unloading ourselves. We lift the part from your truck onto the furnace car and load it back after annealing.
- vehicles up to 30 m long and 6 m wide
- delivery on an agreed date
- support and load distribution planned for heavy parts

Multi-zone control
Every heating zone controlled separately
The furnace heating system is divided into several zones that are controlled independently. This lets us adapt heating to parts whose wall thickness and geometry vary from section to section.
The actual temperature in the material depends not only on the furnace setting but also on wall thickness, weight and how the part is positioned. That is why we define the cycle for the weldment, not just for the furnace set point.
- all furnaces are electrically heated
- temperature is usually held within ±10 °C, ±20 °C in furnace 2
- furnace temperature uniformity certified by Elpro Lepenik
- we anneal to the customer’s process specification
Furnace selection
What we check before accepting a part
A part within the load capacity may still not fit a furnace because of its dimensions or shape. So we check everything.
Dimensions
The part must fit the usable width, height and depth of the furnace.
Weight
Furnace load capacity and how the part is supported.
Material
Composition and properties determine the right heat treatment regime. Besides steels, we also anneal other materials, following the procedure specified by the customer.
Temperature
The furnace must be able to run the specified cycle.
Geometry
Shape, wall thicknesses and hollow sections affect heating and cooling.
Measurement and records
Whether thermocouples on the part are needed and what records you require.
Enquiry
You send the drawing. We choose the right furnace.
Dimensions, weight and material are enough for us to check which furnace fits and confirm a date.
Send an enquiry