Capacities

Annealing furnaces

Four industrial furnaces up to 12.8 m long, 100 t load capacity and 750 °C, with 20 t and 64 t cranes.

Four furnaces

We choose the furnace to fit your weldment

Weldments can be long and narrow, or short but wide and tall. That is why we run four furnaces of different sizes and load capacities.

Furnace 1
100 t
load capacity
W × H
3.4 × 3.6 m
Depth
12.0 m
Max. temperature
650 °C
Furnace 2
8 t
load capacity
W × H
3.0 × 2.7 m
Depth
4.4 m
Max. temperature
580 °C
Furnace 3
80 t
load capacity
W × H
5.3 × 4.0 m
Depth
6.4 m
Max. temperature
650 °C
up to 12 thermocouples
Furnace 4
60 t
load capacity
W × H
3.9 × 4.5 m
Depth
12.8 m
Max. temperature
750 °C
up to 12 thermocouples

Furnace specifications

Figures are indicative; we check the right furnace for each weldment individually.
SpecificationFurnace 1Furnace 2Furnace 3Furnace 4
Width3,400 mm3,000 mm5,300 mm3,900 mm
Height3,600 mm2,700 mm4,000 mm4,500 mm
Depth12,000 mm4,400 mm6,400 mm12,800 mm
Load capacity100,000 kg8,000 kg80,000 kg60,000 kg
Maximum temperature650 °C580 °C650 °C750 °C
Temperature tolerance±10 °C±20 °C±10 °C±10 °C
Heatingelectricelectricelectricelectric
Thermocouples on part––up to 12 thermocouplesup to 12 thermocouples
60 t gantry crane above the annealing furnace

Lifting equipment

20 t and 64 t cranes

We handle loading into the furnace and unloading ourselves. We lift the part from your truck onto the furnace car and load it back after annealing.

  • vehicles up to 30 m long and 6 m wide
  • delivery on an agreed date
  • support and load distribution planned for heavy parts
Inside an annealing furnace with heating elements

Multi-zone control

Every heating zone controlled separately

The furnace heating system is divided into several zones that are controlled independently. This lets us adapt heating to parts whose wall thickness and geometry vary from section to section.

The actual temperature in the material depends not only on the furnace setting but also on wall thickness, weight and how the part is positioned. That is why we define the cycle for the weldment, not just for the furnace set point.

  • all furnaces are electrically heated
  • temperature is usually held within ±10 °C, ±20 °C in furnace 2
  • furnace temperature uniformity certified by Elpro Lepenik
  • we anneal to the customer’s process specification

Furnace selection

What we check before accepting a part

A part within the load capacity may still not fit a furnace because of its dimensions or shape. So we check everything.

Dimensions

The part must fit the usable width, height and depth of the furnace.

Weight

Furnace load capacity and how the part is supported.

Material

Composition and properties determine the right heat treatment regime. Besides steels, we also anneal other materials, following the procedure specified by the customer.

Temperature

The furnace must be able to run the specified cycle.

Geometry

Shape, wall thicknesses and hollow sections affect heating and cooling.

Measurement and records

Whether thermocouples on the part are needed and what records you require.

Enquiry

You send the drawing. We choose the right furnace.

Dimensions, weight and material are enough for us to check which furnace fits and confirm a date.

Send an enquiry