Skip to content
  1. Home
  2. Measurement and documentation

Process control

Measurement and documentation

Automatic cycle control, up to 12 thermocouples on the part and an annealing chart for every weldment.

What you receive

Heat treatment you can prove

For customers who need to demonstrate heat treatment to their own clients or in the technical documentation.

Automatic control

The heat treatment programme runs automatically, from heating to cooling.

  • repeatable cycle
  • monitored from the control room
  • multi-zone control

Thermocouples on the part

In furnaces 3 and 4 we attach up to 12 thermocouples directly to the weldment.

  • thermocouples or MTC
  • measuring points as you specify
  • temperature in the material, not just the furnace

Chart and report

An annealing chart is generated automatically at the end of the cycle.

  • a chart for every cycle
  • a report when thermocouples are used
  • scope agreed in advance
Heating Soaking Furnace cooling In air soak temperature °C time furnace temperature part temperature (thermocouple)
Schematic. Your annealing chart shows the actual measured temperatures and times of your cycle.

Annealing chart

What the chart shows

An annealing chart is a graph of temperature over time: the heating ramp, the soak at the required temperature and cooling.

It gives you a record of the treatment performed and can be added to the part documentation. When thermocouples are attached to the material, the chart also shows the temperature at selected points on the weldment.

Below are two real examples from our furnaces. Customer details have been redacted.

Metalna Termis annealing chart: heating, soak at 580 °C and cooling, six measuring points; customer details redacted
Annealing chartRecord from the furnace control system: six thermocouples on the part, a soak at 580 °C for more than five hours, then controlled cooling.
Metalna Termis stress relieving report with times, temperatures and rates; customer details redacted
Heat treatment reportStress relieving at 671 °C with a 6-hour soak, heating at 30 °C/h and cooling at 28 °C/h, measured with thermocouples.
Annealing furnace no. 2 at Metalna Termis

Furnace or material

Why we measure on the weldment

The furnace can reach its set temperature while a heavy part, because of its thermal mass, lags behind. Temperature also depends on the position in the furnace, wall thickness and geometry.

For demanding procedures we therefore measure the temperature directly on the material. That way we know when the conditions for the next phase of the cycle have been reached.

Before we start

What we agree in advance

For more demanding parts we align the requirements before treatment, so the records match your specifications.

01

Heat treatment cycle

Temperature, soaking time, heating and cooling rates.

02

Measuring points

Number of thermocouples and where they are placed on the part.

03

Scope of documentation

Chart, report and any other records your customer requires.

Enquiry

You send the drawing. We choose the right furnace.

Dimensions, weight and material are enough for us to check which furnace fits and confirm a date.

Send an enquiry
Phone+386 40 529 312
Emailinfo@termis.si
Address
Zagrebška cesta 20
2000 Maribor, Slovenia